• info@labexpo.biz

Spectrophotometer

Single Beam UV/Visible
Spectrophotometer LUS-A10

Wavelength
Range

190-1100nm

Spectral
Bandwidth

1 nm

Wavelength
Accuracy

±0.3nm

Wavelength
Repeatabilit

0.2nm

Single Beam UV/Visible
Spectrophotometer LUS-A11

Wavelength
Range

190-1100nm

Spectral
Bandwidth

1.8 nm

Wavelength
Accuracy

±0.3nm

Wavelength
Repeatabilit

0.2nm

Single Beam UV/Visible
Spectrophotometer LUS-A20

Wavelength
Range

190~1100nm

Setting
Wavelength

Automatic

Spectral
Bandwidth

2nm

Wavelength
Accuracy

±0.5nm

Single Beam UV/Visible
Spectrophotometer LUS-A21

Wavelength
Range

190~1100nm

Setting
Wavelength

Automatic

Spectral
Bandwidth

2nm(Optional
: 0.5nm,

Wavelength
Accuracy

±0.3nm

Single Beam UV/Visible
Spectrophotometer LUS-A30

Wavelength
Range

190~1100nm

Setting
Wavelength

Automatic

Spectral
Bandwidth

4nm

Wavelength
Accuracy

±0.5nm

Single Beam UV/Visible
Spectrophotometer LUS-A40

Wavelength
Range

190-1100nm

Spectral
Bandwidth

0.5/1.0/2.0/
4.0/5.0nm

Wavelength
Accuracy

±0.3nm

Wavelength
Repeatabilit

0.2nm

Single Beam UV/Visible
Spectrophotometer LUS-A22

Wavelength
Range

190 - 1100nm
(step
int

Spectral
Bandwidth

2nm

Wavelength
Accuracy

±1.0nm
(Calibrate
by

Wavelength
Repeatabilit

0.5nm

Double Beam UV/Vis
Spectrophotometer LUS-B10

Wavelength
Range

190-1100nm

Setting
Wavelength

Automatic
adjustment

Spectral
Bandwidth

1.0nm

Wavelength
Accuracy

± 0.3nm

Double Beam UV/Vis
Spectrophotometer LUS-B11

Wavelength
Range

190-1100nm

Spectral
Bandwidth

1.8nm

Wavelength
Accuracy

±0.3nm

Wavelength
Repeatabilit

0.2nm

Double Beam UV/Vis
Spectrophotometer LUS-B12

Wavelength
Range

190~1100nm

Spectral
Bandwidth

1.8nm

Wavelength
Accuracy

±0.5nm

Wavelength
Repeatabilit

0.2nm

Double Beam UV/Vis
Spectrophotometer LUS-B13

Wavelength
Range

190~1100nm

Setting
Wavelength

Automatic

Spectral
Bandwidth

2nm(Optional
: 0.5nm,

Wavelength
Accuracy

±0.3nm

Double Beam UV/Vis
Spectrophotometer LUS-B20

Wavelength
Range

190~900nm

Spectral
Bandwidth

0.1-5.0nm
continuous
a

Wavelength
Accuracy

±0.3nm

Wavelength
Repeatabilit

≤0.1nm

Vis Spectrophotometer LVS-A10

Wavelength
Range

335~1000nm

Setting
Wavelength

332~1003nm

Spectral
Bandwidth

5 nm

Wavelength
Accuracy

±2 nm

Vis Spectrophotometer LVS-A11

Wavelength
Range

325~1000nm

Spectral
Bandwidth

4 nm

Wavelength
Accuracy

±2 nm

Wavelength
Repeatabilit

1nm

Vis Spectrophotometer LVS-B10

Wavelength
Range

325~1000nm

Setting
Wavelength

Automatic

Spectral
Bandwidth

2 nm

Wavelength
Accuracy

±1.0nm

Vis Spectrophotometer LVS-C10

Wavelength
Range

320~1100nm

Spectral
Bandwidth

4nm

Wavelength
Accuracy

±0.5nm

Wavelength
Repeatabilit

0.2nm

Vis Spectrophotometer LVS-C11

Wavelength
Range

320~1000nm

Spectral
Bandwidth

2nm

Wavelength
Accuracy

±0.5nm

Wavelength
Repeatabilit

≤0.2nm

Nano Spectrophotometer LNS-A10

Wavelength
range (nm)

200-800

Wavelength
accuracy
(n

1

Wavelength
Resolution

≤ 3 (FWHM
at Hg 546

Path length
(mm)

0.2 (For
high
concentr

Nano Spectrophotometer LNS-A20

Wavelength
range (nm)

200~850

Wavelength
accuracy
(n

±1

Wavelength
Resolution

2 (FWHM at
Hg 546nm)

Path length
(mm)

1,0.2, (0.1,
0.05 –

Nano Spectrophotometer LNS-A21

Wavelength
range (nm)

200~850

Wavelength
accuracy
(n

±1

Wavelength
Resolution

2 (FWHM at
Hg 546nm)

Path length
(mm)

1,0.2, (0.1,
0.05 –

Nano Spectrophotometer LNS-B10

Wavelength
range (nm)

230, 260,
280

Path length
(mm)

0.2 (For
high
concentr

Minimum
Sample size
(

0.5-2

Absorbance
range

0.02 - 80A
(10 mm
equi

Nano Spectrophotometer LNS-B11

Wavelength
range (nm)

230, 260,
280

Path length
(mm)

1, 0.2

Minimum
Sample size
(

0.3~2

Absorbance
range

0.2~75 (10mm
equivalent

Nano Spectrophotometer LNS-C10

Cuvette

No

Temperature

-

PC

Inbuilt

Wavelength
range (nm)

190~850

Nano Spectrophotometer LNS-C11

Cuvette

Yes

Temperature

-

PC

Inbuilt

Wavelength
range (nm)

190~850

Nano Spectrophotometer LNS-C12

Cuvette

Yes

Temperature

Room
Temperature
42ºC

PC

Inbuilt

Wavelength
range (nm)

190~850

Nano Spectrophotometer LNS-C13

Cuvette

Yes

Temperature

4-42ºC
(Heating &
Coo

PC

Inbuilt

Wavelength
range (nm)

190~850